order-bucket
Metal Building Exterior Walls Insulation

ROCKWOOL PLUS™ MB

ROCKWOOL PLUS MB is a is a lightweight, non-combustible, semi-rigid mineral wool blanket insulation that is designed for pre-engineered metal building construction where an hourly fire rating is not required. 

 

Back

ROCKWOOL PLUS™ MB is a is a lightweight, non-combustible, semi-rigid mineral wool blanket insulation

ROCKWOOL PLUS MB is designed for pre-engineered metal building construction where an hourly fire rating is not required. Insulating buildings with ROCKWOOL PLUS MB will help increase energy efficiency, improve thermal stability and enhance fire protection for the overall comfort and safety of occupants.

Properties:

  • Lightweight, fire-resistant and sound absorbent
  • Strong—well suited for site durability
  • Easy to install, easy to cut
  • Water and moisture resistant—maintains R-value even when wet
  • Does not rot or promote the growth of mildew, fungi or bacteria
  • Sag-resistant for tight fits; high density ROCKWOOL PLUS MB never loses shape
  • Consistent thermal performances with high R-Values
  • ROCKWOOL PLUS MB can contribute to earning LEED® points
Back

Specification & sizes

Compare
Compliance ASTM C553
ASTM C553

Mineral Fiber Blanket Thermal Insulation, Type I, II and III

Density ASTM C303
ASTM C303 Actual Density - 2 lb/ft³ (32 kg/m³)
Dimensions Dimensions
24" x 48" (610 mm x 1219 mm)
Thickness Thickness
2” through 4” (50.8 mm – 101.6 mm) in 1/2" (12.7 mm) increments
5" (127 mm) and 6" (152.4 mm)
Reaction to fire ASTM E84 (UL 723) - CAN/ULC S102 - CAN/ULC S114 - ASTM E136
ASTM E84 (UL 723) Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102 Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114 Determination of Non-Combustibility of Building Materials - Non-Combustible
ASTM E136 Behavior of materials at 750°C - Non-Combustible

Thermal resistance ASTM C518 (C177)
ASTM C518 (C177) R-value / inch @ 75ºF - 4.0 hr.ft2.F/Btu
ASTM C518 (C177) RSI value / 25.4 mm @ 24ºC - 0.70 m2K/W
Acoustical Performance ASTM C423
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC
2.5" 0.34 0.76 1.12 1.05 1.04 1.04 1
3.5" 0.56 0.99 1.17 1.04 1.05 1.05 1.05
6" 1.17 1.2 1.16 1.08 1.08 1.07

1.15

Reaction to moisture ASTM C1104 - ASTM C1338
ASTM C1104 Moisture Sorption - 0.03%
ASTM C1338 Determination of Fungi Resistance - Passed
Corrosion Resistance ASTM C795 - ASTM C665
ASTM C795 Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665 Corrosion of Steel - Passed
Back
ASTM C553

Mineral Fiber Blanket Thermal Insulation, Type I, II and III

Back
ASTM C303 Actual Density - 2 lb/ft³ (32 kg/m³)
Back
24" x 48" (610 mm x 1219 mm)
Back
2” through 4” (50.8 mm – 101.6 mm) in 1/2" (12.7 mm) increments
5" (127 mm) and 6" (152.4 mm)
Back
ASTM E84 (UL 723) Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102 Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114 Determination of Non-Combustibility of Building Materials - Non-Combustible
ASTM E136 Behavior of materials at 750°C - Non-Combustible

Back
ASTM C518 (C177) R-value / inch @ 75ºF - 4.0 hr.ft2.F/Btu
ASTM C518 (C177) RSI value / 25.4 mm @ 24ºC - 0.70 m2K/W
Back
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC
2.5" 0.34 0.76 1.12 1.05 1.04 1.04 1
3.5" 0.56 0.99 1.17 1.04 1.05 1.05 1.05
6" 1.17 1.2 1.16 1.08 1.08 1.07

1.15

Back
ASTM C1104 Moisture Sorption - 0.03%
ASTM C1338 Determination of Fungi Resistance - Passed
Back
ASTM C795 Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665 Corrosion of Steel - Passed
Back

Tools, Guides & Downloads