Party wall Firestopping Interior wall Insulation Exterior Walls Insulation Wood Frame Construction Insulation

ROXUL SAFE™ 45

ROXUL SAFE™ 45 is a semi-rigid stone wool insulation board ideal for firestopping in concealed spaces of multi-unit residential buildings. This product complies with the 2006 Building code 9.10.16.3 (2).

Back
Back

Specification & sizes

Compare
ComplianceASTM C612 - CAN/ULC S702
ASTM C612Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant
CAN/ULC S702Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant
DensityASTM C303
ASTM C303Actual Density - 4.4 lb/ft³ (70 kg/m³)
Dimensional stabilityASTM C356
ASTM C356Linear Shrinkage - <1% @1200°F
DimensionsDimensions
16" x 48" (406 mm x 1219 mm)
24" x 48" (610 mm x 1219 mm)
ThicknessThickness
Product is available in 1” thickness (25.4 mm)
Reaction to fireASTM E84 (UL 723) - CAN/ULC S102 - CAN/ULC S114 - ASTM E136
ASTM E84 (UL 723)Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114Determination of Non-Combustibility of Building Materials - Non-Combustible
ASTM E136Behavior of materials at 750°C - Non-Combustible
Thermal resistanceASTM C518 (C177)
ASTM C518 (C177)

R-value / inch @ 75ºF - 4.2 hr.ft2.F/Btu

RSI value / 25.4 mm @ 24ºC - 0.74 m2K/W

Reaction to moistureASTM C1104 - ASTM C1338
ASTM C1104Moisture Sorption - 0.03%
ASTM C1338 Determination of Fungi Resistance - Passed
Corrosion ResistanceASTM C795 - ASTM C665
ASTM C795Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665Corrosion of Steel - Passed
Back
ASTM C612Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant
CAN/ULC S702Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant
Back
ASTM C303Actual Density - 4.4 lb/ft³ (70 kg/m³)
Back
ASTM C356Linear Shrinkage - <1% @1200°F
Back
16" x 48" (406 mm x 1219 mm)
24" x 48" (610 mm x 1219 mm)
Back
Product is available in 1” thickness (25.4 mm)
Back
ASTM E84 (UL 723)Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S102Flame spread index = 0 ; Smoke developed index = 0
CAN/ULC S114Determination of Non-Combustibility of Building Materials - Non-Combustible
ASTM E136Behavior of materials at 750°C - Non-Combustible
Back
ASTM C518 (C177)

R-value / inch @ 75ºF - 4.2 hr.ft2.F/Btu

RSI value / 25.4 mm @ 24ºC - 0.74 m2K/W

Back
ASTM C1104Moisture Sorption - 0.03%
ASTM C1338 Determination of Fungi Resistance - Passed
Back
ASTM C795Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed
ASTM C665Corrosion of Steel - Passed
Back

Tools, Guides & Downloads

 

 

printpdf
icon
Mid-Rise Wood Frame Construction Guide
Mid-Rise Wood Frame Construction Guide

This Mid-Rise Wood Construction Solutions Guide identifies several common locations where ROCKWOOL insulation can be used effectively in mid-rise wood construction.

pdf
icon
ROCKWOOL ROXUL SAFE Application Guide
ROCKWOOL ROXUL SAFE Application Guide

pdf
icon
Safe Use Instruction Sheet
Safe Use Instruction Sheet

ROCKWOOL provides this SUIS for safe handling and use instructions.

pdf
Back

Questions? Contact Us

If you have technical questions about products or need support for your project, our technical experts are here to help you.

Contact Us

Related products