Fire door OEM Insulation

FABROCK™ HD

FABROCK™ HD is a high-mono-density board ideal for fabrication because of its uniform integrity. With excellent fire, acoustic and thermal properties, FABROCK™ HD is ideal for use in Fire Doors and other OEM applications where rigid board insulation is required.

Back
Back

Specification & sizes

Compare
ComplianceASTM C612
ASTM C612

Mineral Fiber Block and Board Thermal Insulation, Type IVB Compliant

DensityASTM C303
ASTM C303

Actual Density - 12.5 lb/ft³ (200 kg/m³)

Dimensional stabilityASTM C356
ASTM C356

Linear Shrinkage 1.1% @ 1200°F (650°C)

Dimensions

Contact ROCKWOOL for sizing information (1-800-265-6878)

Thickness

Contact ROCKWOOL for sizing information (1-800-265-6878)

 

Reaction to fireASTM E84 (UL 723) - CAN/ULC S102 - CAN/ULC S114
ASTM E84 (UL 723)

Flame spread index = 0 ; Smoke development index = 0

CAN/ULC S102

Flame spread index = 0 ; Smoke development index = 0

CAN/ULC S114

Behavior of materials at 750°C (1382°F) - Non-Combustible

Thermal resistanceASTM C518 (C177)
ASTM C158 (C177) R-value / inch @ 75ºF - 3.8 hr.ft2.F/Btu
 RSI value / 25.4 mm @ 24ºC - 0.67 m2K/W
Acoustical PerformanceASTM C423
Thickness125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 HzNRC
1.0"0.030.410.850.890.890.970.8
2.0"0.390.730.810.860.970.950.85
4.0"0.610.690.790.870.960.970.85
Reaction to moistureASTM C1104 - ASTM C1338 - ASTM E96
ASTM C1104

Moisture Sorption by weight - <1.0%>

ASTM C1338

Determination of Fungi Resistance - Passed

ASTM E96

Water Vapor Transmission, Desiccant Method - 2360 ng/Pa.s.m2 (41 perm)

Compressive strengthASTC C165
ASTC C165

12 psi (85 kPa) @ 10% compression

ASTC C165 (@1" Thickness)

28 psi (190 kPa) @ 25% compression

Corrosion ResistanceASTM C795 - ASTM C665
ASTM C795

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed

ASTM C665

Corrosion of Steel - Passed

Back
ASTM C612

Mineral Fiber Block and Board Thermal Insulation, Type IVB Compliant

Back
ASTM C303

Actual Density - 12.5 lb/ft³ (200 kg/m³)

Back
ASTM C356

Linear Shrinkage 1.1% @ 1200°F (650°C)

Back

Contact ROCKWOOL for sizing information (1-800-265-6878)

Back

Contact ROCKWOOL for sizing information (1-800-265-6878)

 

Back
ASTM E84 (UL 723)

Flame spread index = 0 ; Smoke development index = 0

CAN/ULC S102

Flame spread index = 0 ; Smoke development index = 0

CAN/ULC S114

Behavior of materials at 750°C (1382°F) - Non-Combustible

Back
ASTM C158 (C177) R-value / inch @ 75ºF - 3.8 hr.ft2.F/Btu
 RSI value / 25.4 mm @ 24ºC - 0.67 m2K/W
Back
Thickness125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 HzNRC
1.0"0.030.410.850.890.890.970.8
2.0"0.390.730.810.860.970.950.85
4.0"0.610.690.790.870.960.970.85
Back
ASTM C1104

Moisture Sorption by weight - <1.0%>

ASTM C1338

Determination of Fungi Resistance - Passed

ASTM E96

Water Vapor Transmission, Desiccant Method - 2360 ng/Pa.s.m2 (41 perm)

Back
ASTC C165

12 psi (85 kPa) @ 10% compression

ASTC C165 (@1" Thickness)

28 psi (190 kPa) @ 25% compression

Back
ASTM C795

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed

ASTM C665

Corrosion of Steel - Passed